Channel Master Operation Manual
page 50 RD Instruments
save it in the Channel Master. This procedure assumes that you will be us-
ing the program BBTalk that is supplied by RD Instruments.
a. Connect the Channel Master to the computer and apply power (see
“Setup the Channel Master,” page 10).
b. Start the BBTalk program and establish communications with the
Channel Master. Wakeup the Channel Master by sending a break sig-
nal with the End key.
c. Send the command CR1 to place the Channel Master in the factory de-
fault setup.
d. Send the CB-command that selects the baud rate you wish. The fol-
lowing are the typical CB-command settings for different baud rates
with no parity and 1 stop bit:
Table 9: Baud Rate
BAUD RATE CB-command
1200 CB111
2400 CB211
4800 CB311
9600 CB411 (Default)
19200 CB511
38400 CB611
57600 CB711
115200 CB811
e. In BBTalk, press F5 and change the settings to match your CB com-
mand settings. Press OK to exit the communication setup screen.
f. Send the command CK to save the new baud rate setting.
g. Click File, Close to exit the terminal window.
The Channel Master is now set for the new baud rate. The baud rate will
stay at this setting until you change it back with the CB-command.
Note If you send a BREAK before changing the external device’s
communication parameters, the Channel Master returns to the
communication parameters stored in non-volatile memory
(user settings).